拉力试验机力值不显示可能原因 |
添加时间:2019/10/8 15:54:46 浏览次数: |
拉力试验机力值不显示可能原因 Possible Reasons for Failure to Display Force Value of Tension Testing Machine 拉力机力值不显示有拉力机,拉力试验机的传感器本身故障 The force value of the tension machine does not show that there is a tension machine. The sensor of the tension testing machine itself fails. 拉力试验机力值不显示的拉力机主板和线路故障,处理方法检查拉力机传感器的联接线接触是否良好,可以对传感器的接头重新插拔一下如果没有解决有可能是拉力机主板已损坏。 The main board and line faults of the tension tester are not shown by the force value of the tension tester. The treatment method checks whether the connection of the sensor of the tension tester is in good contact. The joint of the sensor can be re-inserted. If there is no solution, it may be that the main board of the tension tester has been damaged. 拉力机传器感是否损坏,损坏原因有,传感自然老化寿命已到。人为损坏使传感器过载或不小心在测试中传感器与下夹具撞击到了一块。 Whether the transmitter sense of the tension machine is damaged or not, the reasons for the damage are that the natural aging life of the sensor has reached. Man-made damage caused sensor overload or accidental collision between sensor and lower fixture in the test. |